MODE 10 is a new working mode for the Mictrack MT700 & MT710. In this mode, the device can automatically generate multiple sub-alarms and report to the server.
Below, we will explain the details and show you how to set it up correctly.
Command Format
Format: MODE,10,T1,T2
Example: MODE:10,1,07:00
Note: T1 is [0,24] hours, T2 is [00:00,23:59] HH:MM, T2 is UTC time. After setting the alarm clock parameter, the device will automatically generate multiple sub-alarms and limit them to 24 hours according to the value set in T1. If the T1 is 0, it means that only one report will be generated per day.