If you want to adjust/calibrate the (G-sensor) vibration sensitivity on MT700, this command is available.
SMS Command
Command format: #999#user password#wake-up threshold#vibrate threshold#vibrate sensitivity#vibrate detection time##
For example:#999#0000#70#70#2#1##
Reply: SET GSENSOR OK.
USB Command
Command format: 999,wake-up threshold,vibrate threshold,vibrate sensitivity,vibrate detection time
For example:999,70,70,2,1
Reply: 999,OK.
Downlink Command
Command format: GSEN,wake-up threshold,vibrate threshold,vibrate sensitivity,vibrate detection time
For example: GSEN,70,70,2,1
Reply: #IMEI#REPLY#GSEN,OK
Parameter Description
Wake-up Threshold
Used to trigger the transition from idle state to vibration-detection state. Range: 1–125 mg, default: 70 mg.
Vibrate Threshold
The vibration magnitude considered valid during detection. Range: 10–2000 mg, default: 70 mg.
Vibrate Sensitivity
The required number of valid vibration events during detection. Range: 1–32 times, default: 2 times.
Vibrate Detection time
The duration of each vibration-detection cycle. Range: 1–10 minutes, default: 1 minute.
Note
The default values are the optimal combination obtained from field testing. It is not recommended for customers to modify them. If adjustments are necessary, please contact customer support for guidance.
FAQ
GSEN,70,70,2,1.GSEN,65,65,2,1 to improve the sensitivity. If you still want to improve it, please try GSEN,60,60,2,1.